1.1 Overview of AD Systems and Their Products

AD Systems specializes in designing and manufacturing high-performance interior sliding and swinging door systems, catering to healthcare, commercial, and residential markets. Their products are known for exceptional quality, durability, and innovative features such as superior sound attenuation, ADA compliance, and space-saving designs. The ExamSlide system, specifically, is engineered for healthcare facilities, offering precision-crafted frames and hardware that ensure smooth operation and long-lasting performance. AD Systems’ solutions are tailored to meet the demands of modern spaces, providing privacy, efficiency, and aesthetic appeal. Their commitment to excellence has established them as a trusted name in the door systems industry, with over 60,000 installations worldwide.

By combining cutting-edge technology with sustainable practices, AD Systems delivers products that enhance functionality while maintaining sleek, modern designs. Their focus on precision engineering and customer support makes them a preferred choice for professionals seeking reliable door systems.

1.2 Importance of Proper Installation

Proper installation of AD Systems’ ExamSlide door systems is critical to ensure optimal performance, safety, and longevity. Incorrect installation can lead to misalignment, reduced functionality, and potential safety hazards, particularly in healthcare settings where infection control and patient privacy are paramount. Proper installation ensures smooth operation, maintains acoustic integrity, and meets ADA compliance standards. It also prevents premature wear and tear, extending the system’s lifespan. Adhering to installation guidelines guarantees that the door system functions as intended, providing efficient, space-saving solutions for modern healthcare facilities. Additionally, correct installation ensures compliance with fire-rated and smoke-rated assembly requirements, which are essential for safety. By following manufacturer instructions and best practices, installers can deliver a reliable and high-performing door system tailored to specific project needs.

Pre-Installation Requirements

Ensure accurate rough opening dimensions match the door system specifications; Verify door compatibility with the project and confirm all necessary accessories are available before proceeding.

2.1 Checking the Rough Opening Dimensions

Verify the rough opening dimensions match the specified requirements for the AD Systems ExamSlide installation. Ensure the opening height and width align with the project-specific measurements.

This step is crucial to prevent installation delays and ensure proper door operation. Double-check the dimensions against the manufacturer’s guidelines and project plans before proceeding.

The opening must be plumb, level, and square to support the door system’s structural integrity. Any discrepancies may lead to installation issues or compromised performance.

Always refer to the AD Systems installation instructions for precise measurement guidelines and ensure compliance with the project’s technical specifications.

2.2 Verifying Door Compatibility and Accessories

Ensure the AD Systems ExamSlide door system is compatible with the project’s specifications and requirements. Verify that all components, including handles, hinges, and frames, match the order and design plans.

Cross-check the accessories with the manufacturer’s guidelines to confirm they meet the intended use and functionality. This step ensures seamless integration and proper operation of the door system.

Inspect all hardware and accessories for damage or discrepancies. Ensure the correct type and quantity of components are available before proceeding with installation.

Incorrect or missing items can lead to installation issues or delays. Always refer to the AD Systems installation instructions for specific compatibility and accessory requirements.

Installation Process

The installation involves preparing the door system, assembling components, and aligning them with the wall opening. Follow the manufacturer’s instructions for a smooth and proper setup.

3.1 Preparing the Door System for Installation

Begin by carefully unpacking the ExamSlide system, ensuring all components are included and undamaged. Inspect the door frames, tracks, and hardware for any defects or misalignments. Organize the parts according to the installation manual, grouping hardware like rollers, handles, and brackets. Refer to the provided templates or diagrams to understand the assembly sequence. Clean and prepare the door panels, ensuring they are free from dust or debris. Verify that all tools and fasteners are readily available. Double-check compatibility with accessories like locks or soft-close mechanisms. Finally, review the installation manual to familiarize yourself with the process before proceeding. Proper preparation ensures a smooth and efficient installation.

3.2 Assembling and Mounting the Door Frame

Begin by aligning the door frame with the prepared wall opening, ensuring it is level and plumb. Secure the frame to the wall using the provided fasteners, following the manufacturer’s torque specifications. Next, install the track system, attaching it to the framed opening or ceiling as specified. Ensure the track is properly aligned and securely fastened to support the weight of the door. Once the track is in place, attach the rollers or hangers to the door panels, making sure they are evenly spaced and aligned with the track. Finally, carefully lift the door panels and mount them onto the track, ensuring smooth operation. Double-check all connections and tighten any loose fasteners before proceeding to the next step.

Wall Opening Preparation

Proper wall opening preparation ensures a precise fit for AD Systems ExamSlide doors. Verify dimensions match system specifications and make adjustments for accurate installation.

4.1 Ensuring Correct Wall Opening Size

Accurate wall opening size is critical for proper AD Systems ExamSlide installation. Measure the opening to ensure it matches the door system’s specifications exactly. Double-check the dimensions before proceeding, as incorrect sizing can lead to installation issues. Use a tape measure to verify both width and height, and ensure the opening is square. If the wall opening is too small or large, adjust it accordingly. For new constructions, refer to the manufacturer’s guidelines to prep the opening correctly. This step ensures a seamless fit and optimal performance of the door system. Proper alignment and sizing are foundational for smooth operation and longevity of the ExamSlide doors.

4.2 Aligning the Door System with the Wall Opening

Aligning the AD Systems ExamSlide door system with the wall opening is essential for proper functionality and aesthetics. Start by ensuring the door frame is centered within the opening. Use shims to make minor adjustments and achieve a plumb and level position. Double-check the alignment using a spirit level to confirm the frame is perfectly straight. Ensure the door system is evenly spaced around the perimeter to maintain structural integrity. Once aligned, secure the frame firmly to the wall to prevent any shifting during operation. Proper alignment ensures smooth door movement and prevents wear and tear on the system. Misalignment can lead to operational issues, so precision is key in this step.

Final Adjustments and Testing

After installation, test the door’s functionality and safety features to ensure proper operation. Fine-tune the alignment if needed and confirm all components are secure and functioning smoothly.

5.1 Fine-Tuning the Door Alignment

Proper alignment is crucial for smooth operation and longevity of the door system. Begin by ensuring the door is level and plumb, checking both vertically and horizontally. Use shims or adjustment screws to fine-tune the frame and track alignment. Verify that the door glides effortlessly along the track without binding or resistance. Pay attention to the door’s clearance and ensure it seals properly when closed. If necessary, adjust the hinges or rollers to achieve optimal fit and movement. Finally, test the door by sliding it open and closed multiple times to confirm smooth operation and proper alignment. This step ensures the door functions as intended and meets safety standards.

5.2 Testing Door Functionality and Safety Features

After installation, thoroughly test the door system to ensure proper functionality and safety. Check the door’s smooth operation by sliding it open and closed multiple times. Verify that all safety features, such as soft-stop mechanisms or automatic door stops, are functioning correctly. Test the door’s acoustic performance by simulating real-world noise conditions. Ensure compliance with fire-rated and smoke-rated assembly standards, if applicable. Additionally, confirm that the door meets ADA requirements for ease of operation and accessibility. Finally, inspect the door for proper sealing and alignment, ensuring it operates without obstruction or resistance. This step guarantees the door system performs reliably and safely in its intended environment.